tools/epro2/kicad: hierarchical export + global_label + 5-Voltage power ports
Three coupled changes so kicad-cli sch erc runs at the project level (across all sheets of one schematic) instead of single-sheet: 1. (label) → (global_label (shape passive)). EPRO2 nets are project-global by construction (named rails span every page in the SCH and physically wire across PCBs); KiCad's local label is sheet- scoped and triggers `label_dangling` for any name not duplicated on the same page. 2. New root_sch_writer that groups SCH_PAGE docs by their parent SCH (META.schematic), emits one root .kicad_sch per group with one (sheet ...) entry per child, and threads the root-assigned uuid back into each child's (sheet_instances) so KiCad can bind them. --all-sch now defaults to this; --flat falls back to one-file-per-page. 3. EPRO2's "5-Voltage" placeholder COMPONENT (partId pid8a0e77bacb214e, 365 instances on ESP-VoCat) is the editor's power port. The rail name lives in the placement's `Global Net Name` ATTR, not in the PART. We now emit a (global_label "<rail>") at the placement coords whenever that attr is set (101/365 of them on ESP-VoCat — the rest are unconfigured drafts). ESP-VoCat 5 hierarchical roots: 2325 → 2265 violations. Modest because 5 of 6 SCHs are single-page (no cross-sheet nets to resolve), and the one 4-page schematic (CoreBoard) shares only a handful of names across sheets — most net names are de-facto sheet-local. The remaining ~190 pin_not_connected are dominated by 0402-style passives whose pin tip lies on a wire's interior, not at an endpoint; KiCad needs an explicit (junction) at those points and we don't yet emit one. Marked as the next follow-up in log.md. 47 → 52 unit tests pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -100,11 +100,13 @@ def test_text_object_emits_text_block_when_non_empty():
|
||||
assert texts[0][1] == "Hello"
|
||||
|
||||
|
||||
def test_named_wire_emits_label_at_line_start():
|
||||
def test_named_wire_emits_global_label_at_line_start():
|
||||
"""EPRO2 binds wire segments into nets by NAME (WIRE.NET attr), not by
|
||||
geometry alone. Each LINE whose lineGroup points to a WIRE with a NET
|
||||
attr must get a (label "<NET>") at one endpoint — same-named labels on
|
||||
distinct LINEs are how KiCad's ERC recognizes a multi-segment net."""
|
||||
attr gets a (global_label "<NET>") at one endpoint — global, not local,
|
||||
because EPRO2 nets span every page of the schematic and (via PCB) the
|
||||
whole project; local (label) on a single page would always be flagged
|
||||
`label_dangling` for cross-sheet nets."""
|
||||
d = _doc([
|
||||
("w1", {"_type": "WIRE"}),
|
||||
("a1", {"_type": "ATTR", "parentId": "w1", "key": "NET", "value": "GND"}),
|
||||
@@ -115,7 +117,7 @@ def test_named_wire_emits_label_at_line_start():
|
||||
])
|
||||
text = write_sch_page(d, sheet_origin_mm=(0.0, 0.0))
|
||||
p = parse(text)
|
||||
labels = _block(p, "label")
|
||||
labels = _block(p, "global_label")
|
||||
assert len(labels) == 2 # one label per non-degenerate LINE
|
||||
assert all(lab[1] == "GND" for lab in labels)
|
||||
# First label sits at the first LINE's start endpoint
|
||||
@@ -136,10 +138,61 @@ def test_unnamed_wire_emits_no_label():
|
||||
])
|
||||
text = write_sch_page(d, sheet_origin_mm=(0.0, 0.0))
|
||||
p = parse(text)
|
||||
assert _block(p, "label") == []
|
||||
assert _block(p, "global_label") == []
|
||||
assert getattr(write_sch_page, "last_stats").labels == 0
|
||||
|
||||
|
||||
def test_power_port_component_emits_global_label_at_placement():
|
||||
"""EPRO2 represents power rails (VCC/GND/VBUS/...) as generic
|
||||
placeholder COMPONENTs whose net name lives in a `Global Net Name`
|
||||
ATTR on the placement (not on the underlying PART). Without an
|
||||
explicit (global_label) at the pin tip, every such instance reads
|
||||
as pin_not_connected even when the symbol's pin sits on a wire."""
|
||||
d = _doc([
|
||||
("e1", {"_type": "COMPONENT", "partId": "pid8a0e77bacb214e",
|
||||
"x": 100, "y": 50, "rotation": 0}),
|
||||
("a1", {"_type": "ATTR", "parentId": "e1",
|
||||
"key": "Global Net Name", "value": "VBUS"}),
|
||||
])
|
||||
text = write_sch_page(d, sheet_origin_mm=(0.0, 0.0))
|
||||
p = parse(text)
|
||||
labels = _block(p, "global_label")
|
||||
assert len(labels) == 1
|
||||
assert labels[0][1] == "VBUS"
|
||||
at = next(c for c in labels[0] if isinstance(c, list) and c[0] == "at")
|
||||
assert at[1] == 100 * MIL_TO_MM
|
||||
assert at[2] == 50 * MIL_TO_MM
|
||||
|
||||
|
||||
def test_unnamed_power_port_emits_no_label():
|
||||
"""Unnamed placeholder power-ports (Global Net Name absent) stay as
|
||||
bare symbol placements — we have no rail name to bind them to."""
|
||||
d = _doc([
|
||||
("e1", {"_type": "COMPONENT", "partId": "pid8a0e77bacb214e",
|
||||
"x": 0, "y": 0}),
|
||||
])
|
||||
text = write_sch_page(d, sheet_origin_mm=(0.0, 0.0))
|
||||
p = parse(text)
|
||||
assert _block(p, "global_label") == []
|
||||
|
||||
|
||||
def test_sheet_path_and_page_num_propagate_to_sheet_instances():
|
||||
"""When a page is written as a child of a hierarchical root, its
|
||||
(sheet_instances) must echo the uuid the root assigned (path
|
||||
"/<assigned_uuid>") and its hierarchy page number — without that the
|
||||
root can't bind the child and ERC treats it as standalone."""
|
||||
d = _doc([("META", {"_type": "META", "title": "child"})])
|
||||
text = write_sch_page(
|
||||
d, sheet_path="/22222222-3333-4444-5555-666666666666", page_num=3,
|
||||
)
|
||||
p = parse(text)
|
||||
inst = _block(p, "sheet_instances")[0]
|
||||
path = next(c for c in inst if isinstance(c, list) and c[0] == "path")
|
||||
assert path[1] == "/22222222-3333-4444-5555-666666666666"
|
||||
page = next(c for c in path if isinstance(c, list) and c[0] == "page")
|
||||
assert page[1] == "3"
|
||||
|
||||
|
||||
def test_non_sch_page_doc_rejected():
|
||||
d = Document(doc_uuid="x", doc_type="PCB")
|
||||
try:
|
||||
|
||||
Reference in New Issue
Block a user